HNLM-100B series of ultrasonic level meter split

HNLM-100B series of ultrasonic level meter split

Model No.︰HNLM-100B

Brand Name︰Harhn

Country of Origin︰China

Unit Price︰CNY ¥ 3500 / pc

Minimum Order︰1 pc

Inquire Now

Product Description

Ultra Liquid Information:
HNLM-100 Series Ultrasonic Level Meter is an intelligent non-contact liquid (material) level measurement instruments. Product has an automatic power adjustment, gain control, temperature compensation, the use of advanced detection technology and computer technology to improve the instrument's measurement accuracy, there is the interference echo suppression function, to ensure real measurement results. Products can be widely used in various height measurements of liquids and solid materials can also be used to measure distance.

Ultrasonic liquid (material) level meter is divided into a smart body size and sub two types of smart sub-size and two-wire and four-wire two kinds.

HNLM-100B series of ultrasonic level meter split

Outline

HNLM-100B series split ultrasonic level meter is an intelligent non-contact liquid (material) level measurement instruments. Product has an automatic power adjustment, gain control, temperature compensation, the use of advanced detection technology and computer technology to improve the instrument's measurement accuracy, there is the interference echo suppression function, to ensure real measurement results. Products can be widely used in various height measurements of liquids and solid materials can also be used to measure distance.

Ultrasonic liquid (material) level meter is divided into a smart body size and sub two types of intelligence but also for two-wire and four-wire two kinds. Here are split ultrasonic level meter.

First, the main parameters
Four-wire system
Power: DC-24v (18v-30v), (sub-size AC-220v)
Output: 4-20mA (16 bit D / A converter), RS485
Range: 0-20m (any segment) (remote range: 0-40m)
Blind: 0.3-0.6m resolution: 1mm
Accuracy: 0.25% Ambient temperature: -25 ℃ -60 ℃
Protection class: IP65 (remote version IP67)

Two-wire
Power: DC-24v (24v-30v)
Output: 4-20mA
Range: 0-10m (any section)
Blind: 0.3-0.6m
Resolution: 1mm
Accuracy: 0.25%
Ambient temperature: -25 ℃ -60 ℃
Protection: IP65

Second, the installation and wiring

HNLM-100B series of ultrasonic level meter split installation
The instrument easy to install, and can be directly used threaded nut on the sensor installation, common installation method flanges, brackets and riser installation.

Notes on Installation:
  ★ Do not allow the probe and the surface perpendicular to the non-state
  ★ Do not install from the vessel too close
  ★ Do not install above it in the sonic barrier during transmission
  ★ Do not install in a vacuum environment

If unknown: please contact customer service